Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Absorption Correction Method for Simultaneous Spectrophotometric Estimation of Flunarizine Dihydrochloride and Propranolol HCl in Combined Capsule Dosage Form


Affiliations
1 Vidyabharati College of Pharmacy, C.K. Naidu Road, Camp, Amravati-444602(M.S.), India
     

   Subscribe/Renew Journal


A new, simple, sensitive, accurate and precise UV ‐ spectrophotometric absorption correction method for simultaneous estimation of flunarizine dihydrochloride and propranolol HCl in capsule dosage form has been developed and validated for accuracy, precision, ruggedness, linearity and range. The wavelengths selected for estimation of drugs were 253.2 nm for flunarizine dihydrochloride and 288.8 nm for propranolol HCl. Linearity for detector response for flunarizine dihydrochloride and propranolol HCl were 1-25 µg/ml and 4-100 μg/ml respectively. The method gives results for high accuracy and high recovery of 99.15±1.37 and 100.02±0.89 for flunarizine dihydrochloride and propranolol HCl respectively. % R.S.D. Values for marketed formulation analysis were found to be less than 2 which indicated good precision and reproducibility of the method.

Keywords

Flunarizine dihydrochloride, Propranolol HCl, Absorption correction method
Subscription Login to verify subscription
User
Notifications
Font Size



  • Absorption Correction Method for Simultaneous Spectrophotometric Estimation of Flunarizine Dihydrochloride and Propranolol HCl in Combined Capsule Dosage Form

Abstract Views: 582  |  PDF Views: 0

Authors

Sangita W. Chapke
Vidyabharati College of Pharmacy, C.K. Naidu Road, Camp, Amravati-444602(M.S.), India
Madhuri D. Game
Vidyabharati College of Pharmacy, C.K. Naidu Road, Camp, Amravati-444602(M.S.), India

Abstract


A new, simple, sensitive, accurate and precise UV ‐ spectrophotometric absorption correction method for simultaneous estimation of flunarizine dihydrochloride and propranolol HCl in capsule dosage form has been developed and validated for accuracy, precision, ruggedness, linearity and range. The wavelengths selected for estimation of drugs were 253.2 nm for flunarizine dihydrochloride and 288.8 nm for propranolol HCl. Linearity for detector response for flunarizine dihydrochloride and propranolol HCl were 1-25 µg/ml and 4-100 μg/ml respectively. The method gives results for high accuracy and high recovery of 99.15±1.37 and 100.02±0.89 for flunarizine dihydrochloride and propranolol HCl respectively. % R.S.D. Values for marketed formulation analysis were found to be less than 2 which indicated good precision and reproducibility of the method.

Keywords


Flunarizine dihydrochloride, Propranolol HCl, Absorption correction method

References